NewTom (Cefla)current

NewTom (Cefla) NewTom VGi evo
CBCT capability & upgrade report

NewTom VGi vertical CBCT · released 2014 · 12 yrs in service · current
✓ Works with Alvea. Your NewTom (Cefla) NewTom VGi evo produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution100 µm voxel
Field of view5–24 cm
Capture modes5x5, 8x8, 10x10, 16x16, 24x19
DetectorAmorphous silicon flat panel
Tube voltage110–110 kVp
Tube current1–20 mA
Scan time~18 s (CBCT); ~90 s reconstruction
Released2014
In service12 years
StatusCurrent
Export pathStandard DICOM
Market positionHigh-end large-FOV vertical CBCT for maxillofacial/ENT and implant centers

Where the NewTom (Cefla) NewTom VGi evo stands today

  • Resolution holds up: at its sharpest (100µm voxel) it's still in the fine-detail tier the newest units sell on. You are not behind on image quality.
  • Field of view reaches 24cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • At 12 years (2014) it's aging but not obsolete. This is exactly the window resellers target for a trade-up you may not need yet.
  • Detector: Amorphous silicon flat panel.

What it already does that most practices don't use

  • Multiple FOV modes (5x5, 8x8, 10x10, 16x16, 24x19). Most operators leave it on one preset — the larger modes are already paid for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the NewTom (Cefla) NewTom VGi evo

  • UpgradeEvolution of NewTom VGi; extends max FOV up to 24x19 cm for full head-and-neck; ECO Scan dose-reduction mode; 0.3 mm focal spot.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

NewTom (Cefla) NewTom VGi evo — common questions

Can Alvea use scans from the NewTom (Cefla) NewTom VGi evo?
Yes. The NewTom (Cefla) NewTom VGi evo exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
How much does it cost to repair a NewTom (Cefla) NewTom VGi evo?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the NewTom (Cefla) NewTom VGi evo?
The NewTom (Cefla) NewTom VGi evo reaches 24 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a NewTom (Cefla) NewTom VGi evo scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my NewTom (Cefla) unit → Try it on one of my scans — first one's free