NewTom (Cefla) NewTom 5G XL
CBCT capability & upgrade report
Specifications
| Sharpest resolution | 150 µm voxel |
|---|---|
| Field of view | 6–21 cm |
| Capture modes | 6x6, 8x5, 8x8, 10x5, 10x10, 12x8, 15x5, 15x12, 15x22, 18x16, 21x19, 21x28 (eXtra FOV) |
| Detector | Amorphous silicon flat panel |
| Released | 2014 |
| In service | 12 years |
| Status | Discontinued |
| Export path | Standard DICOM |
| Market position | Legacy extra-large-FOV supine CBCT for full craniofacial / ENT / vet |
Where the NewTom (Cefla) NewTom 5G XL stands today
- Resolution is solid mainstream (150µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
- Field of view reaches 21cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
- At 12 years (2014) it's aging but not obsolete. This is exactly the window resellers target for a trade-up you may not need yet.
- Detector: Amorphous silicon flat panel.
- This model is no longer sold new — which means parts, service, and software support are the thing to verify before any new spend.
What it already does that most practices don't use
- Multiple FOV modes (6x6, 8x5, 8x8, 10x5, 10x10, 12x8, 15x5, 15x12, 15x22, 18x16, 21x19, 21x28 (eXtra FOV)). Most operators leave it on one preset — the larger modes are already paid for.
- Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.
Upgrade paths for the NewTom (Cefla) NewTom 5G XL
- UpgradeExtended-FOV version of the 5G; native FOV 21x19 cm with eXtra FOV stitch up to 21x28 cm; also sold in veterinary configuration.
- NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
- ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.
Repair vs. replace: what it costs
Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.
Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.
Replace: a comparable unit runs roughly used only. The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.
Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.
NewTom (Cefla) NewTom 5G XL — common questions
- Can Alvea use scans from the NewTom (Cefla) NewTom 5G XL?
- Yes. The NewTom (Cefla) NewTom 5G XL exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
- Is the NewTom (Cefla) NewTom 5G XL discontinued, and what replaced it?
- The NewTom (Cefla) NewTom 5G XL is no longer sold new. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
- How much does a NewTom (Cefla) NewTom 5G XL cost?
- A comparable NewTom (Cefla) NewTom 5G XL runs roughly used only. Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
- How much does it cost to repair a NewTom (Cefla) NewTom 5G XL?
- The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
- What is the field of view on the NewTom (Cefla) NewTom 5G XL?
- The NewTom (Cefla) NewTom 5G XL reaches 21 cm, enough to capture both arches in one scan — a mode most practices never switch to.
See what a NewTom (Cefla) NewTom 5G XL scan becomes.
Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.
Check my NewTom (Cefla) unit → Try it on one of my scans — first one's free