NewTom (Cefla) NewTom 3G
CBCT capability & upgrade report
Specifications
| Sharpest resolution | 190 µm voxel |
|---|---|
| Field of view | 10–20 cm |
| Capture modes | 10x10, 15x15, 20x20 |
| Detector | Image intensifier (supine gantry) |
| Scan time | ~36 s |
| Released | 2004 |
| In service | 22 years |
| Status | Legacy |
| Export path | Standard DICOM |
| Current successor | NewTom VG / VGi |
| Market position | Early-generation supine CBCT (historic), image-intensifier era |
Where the NewTom (Cefla) NewTom 3G stands today
- Resolution is the dated part (190µm at best). It still produces a usable volume, but this is the spec a salesman will push you on.
- Field of view reaches 20cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
- It's 22 years old (2004) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
- Detector: Image intensifier (supine gantry).
- This model is no longer sold new (succeeded by the NewTom VG / VGi) — which means parts, service, and software support are the thing to verify before any new spend.
What it already does that most practices don't use
- Multiple FOV modes (10x10, 15x15, 20x20). Most operators leave it on one preset — the larger modes are already paid for.
- Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.
Upgrade paths for the NewTom (Cefla) NewTom 3G
- UpgradeThird-generation supine NewTom; widest FOV of its time (20 cm diameter); three selectable FOVs; halved scan time vs predecessor. Evolved from NewTom 9000/QR-DVT.
- SuccessorThe NewTom VG / VGi is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
- NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
- ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.
Repair vs. replace: what it costs
Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.
Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.
Replace: a comparable unit runs roughly used only. The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.
Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.
NewTom (Cefla) NewTom 3G — common questions
- Can Alvea use scans from the NewTom (Cefla) NewTom 3G?
- Yes. The NewTom (Cefla) NewTom 3G exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
- Is the NewTom (Cefla) NewTom 3G discontinued, and what replaced it?
- The NewTom (Cefla) NewTom 3G is no longer sold new; its successor is the NewTom VG / VGi. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
- How much does a NewTom (Cefla) NewTom 3G cost?
- A comparable NewTom (Cefla) NewTom 3G runs roughly used only. Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
- How much does it cost to repair a NewTom (Cefla) NewTom 3G?
- The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
- What is the field of view on the NewTom (Cefla) NewTom 3G?
- The NewTom (Cefla) NewTom 3G reaches 20 cm, enough to capture both arches in one scan — a mode most practices never switch to.
See what a NewTom (Cefla) NewTom 3G scan becomes.
Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.
Check my NewTom (Cefla) unit → Try it on one of my scans — first one's free