NewTom (Cefla)discontinued

NewTom (Cefla) NewTom 5G
CBCT capability & upgrade report

NewTom supine/gantry CBCT · released 2011 · 15 yrs in service · discontinued
✓ Works with Alvea. Your NewTom (Cefla) NewTom 5G produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution75 µm voxel
Field of view6–18 cm
Capture modes6x6, 8x8, 12x8, 15x5, 15x12, 18x16
DetectorAmorphous silicon flat panel (14-bit acquisition / 16-bit reconstruction)
Released2011
In service15 years
StatusDiscontinued
Export pathStandard DICOM
Current successorNewTom 5G XL / VGi evo
Market positionLegacy high-end large-FOV supine CBCT for maxillofacial/implant/ENT

Where the NewTom (Cefla) NewTom 5G stands today

  • Resolution holds up: at its sharpest (75µm voxel) it's still in the fine-detail tier the newest units sell on. You are not behind on image quality.
  • Field of view reaches 18cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • It's 15 years old (2011) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
  • Detector: Amorphous silicon flat panel (14-bit acquisition / 16-bit reconstruction).
  • This model is no longer sold new (succeeded by the NewTom 5G XL / VGi evo) — which means parts, service, and software support are the thing to verify before any new spend.

What it already does that most practices don't use

  • Multiple FOV modes (6x6, 8x8, 12x8, 15x5, 15x12, 18x16). Most operators leave it on one preset — the larger modes are already paid for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the NewTom (Cefla) NewTom 5G

  • UpgradeGantry-style supine/seated large-FOV CBCT; FDA cleared 2011; distributed in US by ImageWorks. ~7 FOVs, max 18x16 cm, voxel to 0.075 mm.
  • SuccessorThe NewTom 5G XL / VGi evo is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.

Replace: a comparable unit runs roughly used only. The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

NewTom (Cefla) NewTom 5G — common questions

Can Alvea use scans from the NewTom (Cefla) NewTom 5G?
Yes. The NewTom (Cefla) NewTom 5G exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
Is the NewTom (Cefla) NewTom 5G discontinued, and what replaced it?
The NewTom (Cefla) NewTom 5G is no longer sold new; its successor is the NewTom 5G XL / VGi evo. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
How much does a NewTom (Cefla) NewTom 5G cost?
A comparable NewTom (Cefla) NewTom 5G runs roughly used only. Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
How much does it cost to repair a NewTom (Cefla) NewTom 5G?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the NewTom (Cefla) NewTom 5G?
The NewTom (Cefla) NewTom 5G reaches 18 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a NewTom (Cefla) NewTom 5G scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my NewTom (Cefla) unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.