i-CAT (Dentsply Sirona) i-CAT FLX V17
CBCT capability & upgrade report

i-CAT FLX V-Series · released 2016 · 10 yrs in service · current
✓ Works with Alvea. Your i-CAT (Dentsply Sirona) i-CAT FLX V17 produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution125 µm voxel
Field of view8–23 cm
Capture modes8x5, 8x8, 16x4, 16x6, 16x8, 16x10, 16x11, 16x13, 23x17
DetectorAmorphous silicon flat panel (24.2 x 19.3 cm sensor, 1536 x 1920 matrix, 127 um pixel pitch)
Tube voltage120–120 kVp
Tube current3–7 mA
Scan time4.8 s (13x16 ceph-height 3D) up to 40 s
Pan / CephIntegrated 2D + 3D
Released2016
In service10 years
StatusCurrent
Export pathStandard DICOM
Market positionTop large-FOV V-Series for full cranial-height 3D, ortho and airway; flagship of the current i-CAT line

Where the i-CAT (Dentsply Sirona) i-CAT FLX V17 stands today

  • Resolution is solid mainstream (125µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
  • Field of view reaches 23cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • At 10 years (2016) it's aging but not obsolete. This is exactly the window resellers target for a trade-up you may not need yet.
  • Detector: Amorphous silicon flat panel (24.2 x 19.3 cm sensor, 1536 x 1920 matrix, 127 um pixel pitch).

What it already does that most practices don't use

  • Multiple FOV modes (8x5, 8x8, 16x4, 16x6, 16x8, 16x10, 16x11, 16x13, 23x17). Most operators leave it on one preset — the larger modes are already paid for.
  • The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the i-CAT (Dentsply Sirona) i-CAT FLX V17

  • UpgradeTop tier; full 23 dia x 17 cm FOV unlocked; V8/V10 units upgrade to V17 by software license
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

i-CAT (Dentsply Sirona) i-CAT FLX V17 — common questions

Can Alvea use scans from the i-CAT (Dentsply Sirona) i-CAT FLX V17?
Yes. The i-CAT (Dentsply Sirona) i-CAT FLX V17 exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
How much does it cost to repair a i-CAT (Dentsply Sirona) i-CAT FLX V17?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the i-CAT (Dentsply Sirona) i-CAT FLX V17?
The i-CAT (Dentsply Sirona) i-CAT FLX V17 reaches 23 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a i-CAT (Dentsply Sirona) i-CAT FLX V17 scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my i-CAT (Dentsply Sirona) unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.