i-CAT (Dentsply Sirona)legacy

i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum)
CBCT capability & upgrade report

i-CAT · released 2008 · 18 yrs in service · legacy
✓ Works with Alvea. Your i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution125 µm voxel
Field of view8–23 cm
Capture modes8x8, 4x16, 6x16, 8x16, 10x16, 11x16, 13x16, 17x23 (extended)
DetectorAmorphous silicon flat panel sensor with CsI scintillator
Tube voltage120–120 kVp
Tube current3–8 mA
Scan time5 / 8.5 / 26 s
Pan / CephIntegrated 2D + 3D
Released2008
In service18 years
StatusLegacy
Export pathStandard DICOM
Current successori-CAT FLX
Market positionNamed large-FOV configuration of the Next Generation platform (17 cm height x 19/23 cm); common in published CBCT accuracy studies

Where the i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) stands today

  • Resolution is solid mainstream (125µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
  • Field of view reaches 23cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • It's 18 years old (2008) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
  • Detector: Amorphous silicon flat panel sensor with CsI scintillator.
  • This model is no longer sold new (succeeded by the i-CAT FLX) — which means parts, service, and software support are the thing to verify before any new spend.

What it already does that most practices don't use

  • Multiple FOV modes (8x8, 4x16, 6x16, 8x16, 10x16, 11x16, 13x16, 17x23 (extended)). Most operators leave it on one preset — the larger modes are already paid for.
  • The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum)

  • SuccessorThe i-CAT FLX is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.

Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) — common questions

Can Alvea use scans from the i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum)?
Yes. The i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
Is the i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) discontinued, and what replaced it?
The i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) is no longer sold new; its successor is the i-CAT FLX. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
How much does it cost to repair a i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum)?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum)?
The i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) reaches 23 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a i-CAT (Dentsply Sirona) i-CAT 17-19 (Platinum) scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my i-CAT (Dentsply Sirona) unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.