i-CAT (Dentsply Sirona) i-CAT FLX MV
CBCT capability & upgrade report
Specifications
| Sharpest resolution | 125 µm voxel |
|---|---|
| Field of view | 6–15.5 cm |
| Capture modes | 85x40 mm, 85x85 mm, 155x60 mm, 155x85 mm |
| Detector | Amorphous silicon flat panel sensor |
| Tube voltage | 120–120 kVp |
| Tube current | 3–7 mA |
| Scan time | 4.9 to 26 s (CBCT) |
| Pan / Ceph | Integrated 2D + 3D |
| Released | 2014 |
| In service | 12 years |
| Status | Discontinued |
| Export path | Standard DICOM |
| Market position | Medium-FOV, lower-cost member of the FLX family capturing both arches plus TMJs; the FLX line's value/entry option |
Where the i-CAT (Dentsply Sirona) i-CAT FLX MV stands today
- Resolution is solid mainstream (125µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
- Field of view reaches 15.5cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
- At 12 years (2014) it's aging but not obsolete. This is exactly the window resellers target for a trade-up you may not need yet.
- Detector: Amorphous silicon flat panel sensor.
- This model is no longer sold new — which means parts, service, and software support are the thing to verify before any new spend.
What it already does that most practices don't use
- Multiple FOV modes (85x40 mm, 85x85 mm, 155x60 mm, 155x85 mm). Most operators leave it on one preset — the larger modes are already paid for.
- The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
- Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.
Upgrade paths for the i-CAT (Dentsply Sirona) i-CAT FLX MV
- NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
- ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.
Repair vs. replace: what it costs
Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.
Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.
Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.
Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.
i-CAT (Dentsply Sirona) i-CAT FLX MV — common questions
- Can Alvea use scans from the i-CAT (Dentsply Sirona) i-CAT FLX MV?
- Yes. The i-CAT (Dentsply Sirona) i-CAT FLX MV exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
- Is the i-CAT (Dentsply Sirona) i-CAT FLX MV discontinued, and what replaced it?
- The i-CAT (Dentsply Sirona) i-CAT FLX MV is no longer sold new. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
- How much does it cost to repair a i-CAT (Dentsply Sirona) i-CAT FLX MV?
- The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
- What is the field of view on the i-CAT (Dentsply Sirona) i-CAT FLX MV?
- The i-CAT (Dentsply Sirona) i-CAT FLX MV reaches 15.5 cm, enough to capture both arches in one scan — a mode most practices never switch to.
See what a i-CAT (Dentsply Sirona) i-CAT FLX MV scan becomes.