J. Moritadiscontinued

J. Morita Veraviewepocs 3D R100
CBCT capability & upgrade report

Veraviewepocs · released 2013 · 13 yrs in service · discontinued
✓ Works with Alvea. Your J. Morita Veraviewepocs 3D R100 produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution125 µm voxel
Field of view4–10 cm
Capture modes4x4, 4x8, 8x5, 8x8, R100 10x5 (Reuleaux), R100 10x8 (Reuleaux)
DetectorFlat panel
Tube voltage60–80 kVp
Tube current1–10 mA
Scan time~9.4 s (3D)
Pan / CephIntegrated 2D + 3D
Released2013
In service13 years
StatusDiscontinued
Export pathStandard DICOM
Current successorVeraview X800
Market positionMid-range hybrid pan-ceph-CBCT, predecessor to X800

Where the J. Morita Veraviewepocs 3D R100 stands today

  • Resolution is solid mainstream (125µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
  • Field of view tops out at 10cm — single-arch range. Good for localized implant work; whole-jaw cases need the larger-FOV path (below).
  • It's 13 years old (2013) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
  • Detector: Flat panel.
  • This model is no longer sold new (succeeded by the Veraview X800) — which means parts, service, and software support are the thing to verify before any new spend.

What it already does that most practices don't use

  • Multiple FOV modes (4x4, 4x8, 8x5, 8x8, R100 10x5 (Reuleaux), R100 10x8 (Reuleaux)). Most operators leave it on one preset — the larger modes are already paid for.
  • The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the J. Morita Veraviewepocs 3D R100

  • UpgradeHybrid pan/(ceph)/CBCT; introduced Reuleaux (convex-triangle) full-arch R100 FOV ~Ø100 equivalent; 125 um voxel; dose-reduction mode. Superseded by Veraview X800.
  • SuccessorThe Veraview X800 is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.

Replace: a comparable unit runs roughly used only. The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

J. Morita Veraviewepocs 3D R100 — common questions

Can Alvea use scans from the J. Morita Veraviewepocs 3D R100?
Yes. The J. Morita Veraviewepocs 3D R100 exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
Is the J. Morita Veraviewepocs 3D R100 discontinued, and what replaced it?
The J. Morita Veraviewepocs 3D R100 is no longer sold new; its successor is the Veraview X800. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
How much does a J. Morita Veraviewepocs 3D R100 cost?
A comparable J. Morita Veraviewepocs 3D R100 runs roughly used only. Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
How much does it cost to repair a J. Morita Veraviewepocs 3D R100?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the J. Morita Veraviewepocs 3D R100?
The J. Morita Veraviewepocs 3D R100 reaches 10 cm, single-arch range suited to localized implant work.
Your cone-beam, chairside

See what a J. Morita Veraviewepocs 3D R100 scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my J. Morita unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.