Asahi Roentgendiscontinued

Asahi Roentgen Alphard VEGA 3030
CBCT capability & upgrade report

Alphard · released 2007 · 19 yrs in service · discontinued
✓ Works with Alvea. Your Asahi Roentgen Alphard VEGA 3030 produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Field of view5.1–20 cm
Capture modesD mode 5.1x5.1, I mode 10.2x10.2, P mode 15.4x15.4, C mode 20x17.9
DetectorFlat panel
Tube voltage60–100 kVp
Tube current2–15 mA
Scan timeup to ~17 s
Pan / CephIntegrated 2D + 3D
Released2007
In service19 years
StatusDiscontinued
Export pathStandard DICOM
Current successorAUGE SOLIO / SOLIO X
Market positionLegacy large-FOV seated CBCT for maxillofacial/craniofacial imaging

Where the Asahi Roentgen Alphard VEGA 3030 stands today

  • Field of view reaches 20cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • It's 19 years old (2007) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
  • Detector: Flat panel.
  • This model is no longer sold new (succeeded by the AUGE SOLIO / SOLIO X) — which means parts, service, and software support are the thing to verify before any new spend.

What it already does that most practices don't use

  • Multiple FOV modes (D mode 5.1x5.1, I mode 10.2x10.2, P mode 15.4x15.4, C mode 20x17.9). Most operators leave it on one preset — the larger modes are already paid for.
  • The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the Asahi Roentgen Alphard VEGA 3030

  • UpgradeSeated large-FOV CBCT with four CT modes (Dental/Implant/Panoramic/Cephalo); very large C-mode FOV (Ø200xH179 mm) for full craniofacial. FDA cleared 2007 as Model X178 (K072574).
  • SuccessorThe AUGE SOLIO / SOLIO X is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.

Replace: a comparable unit runs roughly used only. The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

Asahi Roentgen Alphard VEGA 3030 — common questions

Can Alvea use scans from the Asahi Roentgen Alphard VEGA 3030?
Yes. The Asahi Roentgen Alphard VEGA 3030 exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
Is the Asahi Roentgen Alphard VEGA 3030 discontinued, and what replaced it?
The Asahi Roentgen Alphard VEGA 3030 is no longer sold new; its successor is the AUGE SOLIO / SOLIO X. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
How much does a Asahi Roentgen Alphard VEGA 3030 cost?
A comparable Asahi Roentgen Alphard VEGA 3030 runs roughly used only. Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
How much does it cost to repair a Asahi Roentgen Alphard VEGA 3030?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the Asahi Roentgen Alphard VEGA 3030?
The Asahi Roentgen Alphard VEGA 3030 reaches 20 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a Asahi Roentgen Alphard VEGA 3030 scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my Asahi Roentgen unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.