Xorancurrent

Xoran MiniCAT IQ
CBCT capability & upgrade report

MiniCAT · released 2018 · 8 yrs in service · current
✓ Works with Alvea. Your Xoran MiniCAT IQ produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution70 µm voxel
Field of view16.5–16.5 cm
Capture modes16.5cm diameter x 12cm axial (max)
Released2018
In service8 years
StatusCurrent
Export pathStandard DICOM
Market positionPoint-of-care ENT/sinus CBCT, dental-adjacent

Where the Xoran MiniCAT IQ stands today

  • Resolution holds up: at its sharpest (70µm voxel) it's still in the fine-detail tier the newest units sell on. You are not behind on image quality.
  • Field of view reaches 16.5cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • At 8 years (2018) it's current-generation. There is no hardware reason to replace it — the value left on the table is in how you use it.

What it already does that most practices don't use

  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the Xoran MiniCAT IQ

  • UpgradeCompact seated/point-of-care CBCT for sinuses, temporal bone and skull base. Primarily an ENT device, dental-adjacent (used for sinus/implant and OMFS-related imaging). No pano/ceph.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

Xoran MiniCAT IQ — common questions

Can Alvea use scans from the Xoran MiniCAT IQ?
Yes. The Xoran MiniCAT IQ exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
How much does it cost to repair a Xoran MiniCAT IQ?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the Xoran MiniCAT IQ?
The Xoran MiniCAT IQ reaches 16.5 cm, enough to capture both arches in one scan — a mode most practices never switch to.