Soredex SCANORA 3D
CBCT capability & upgrade report
Specifications
| Sharpest resolution | 133 µm voxel |
|---|---|
| Field of view | 6–14.5 cm |
| Capture modes | 60x60 mm, 75x100 mm, 100x75 mm, 100x130 mm, 130x145 mm |
| Detector | amorphous silicon flat panel |
| Tube voltage | 85–90 kVp |
| Tube current | 4–15 mA |
| Scan time | ~20 s (3D) |
| Released | 2009 |
| In service | 17 years |
| Status | Legacy |
| Export path | DICOM 3.0 export |
| Current successor | SCANORA 3Dx |
| Market position | Mid-FOV CBCT for implant, ENT/sinus and oral surgery |
Where the Soredex SCANORA 3D stands today
- Resolution is solid mainstream (133µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
- Field of view reaches 14.5cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
- It's 17 years old (2009) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
- Detector: amorphous silicon flat panel.
- This model is no longer sold new (succeeded by the SCANORA 3Dx) — which means parts, service, and software support are the thing to verify before any new spend.
What it already does that most practices don't use
- Multiple FOV modes (60x60 mm, 75x100 mm, 100x75 mm, 100x130 mm, 130x145 mm). Most operators leave it on one preset — the larger modes are already paid for.
- Output/networking: DICOM 3.0 export. That export path is what lets a scan leave the machine and become something a patient can actually look at.
Upgrade paths for the Soredex SCANORA 3D
- UpgradeMulti-FOV dedicated CBCT (also offered an optional panoramic program on some configs). Several selectable cylinder FOVs from 60x60 mm up to ~130x145 mm; isotropic voxels 133-350 um. Superseded by SCANORA 3Dx (wider FOV, finer voxel).
- SuccessorThe SCANORA 3Dx is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
- NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
- ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.
Repair vs. replace: what it costs
Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.
Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.
Replace: a comparable unit runs roughly ~$20k-$45k used (new discontinued). The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.
Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.
Soredex SCANORA 3D — common questions
- Can Alvea use scans from the Soredex SCANORA 3D?
- Yes. The Soredex SCANORA 3D exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
- Is the Soredex SCANORA 3D discontinued, and what replaced it?
- The Soredex SCANORA 3D is no longer sold new; its successor is the SCANORA 3Dx. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
- How much does a Soredex SCANORA 3D cost?
- A comparable Soredex SCANORA 3D runs roughly ~$20k-$45k used (new discontinued). Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
- How much does it cost to repair a Soredex SCANORA 3D?
- The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
- What is the field of view on the Soredex SCANORA 3D?
- The Soredex SCANORA 3D reaches 14.5 cm, enough to capture both arches in one scan — a mode most practices never switch to.
See what a Soredex SCANORA 3D scan becomes.
Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.
Check my Soredex unit → Try it on one of my scans — first one's free