Soredexlegacy

Soredex SCANORA 3D
CBCT capability & upgrade report

SCANORA 3D · released 2009 · 17 yrs in service · legacy
✓ Works with Alvea. Your Soredex SCANORA 3D produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution133 µm voxel
Field of view6–14.5 cm
Capture modes60x60 mm, 75x100 mm, 100x75 mm, 100x130 mm, 130x145 mm
Detectoramorphous silicon flat panel
Tube voltage85–90 kVp
Tube current4–15 mA
Scan time~20 s (3D)
Released2009
In service17 years
StatusLegacy
Export pathDICOM 3.0 export
Current successorSCANORA 3Dx
Market positionMid-FOV CBCT for implant, ENT/sinus and oral surgery

Where the Soredex SCANORA 3D stands today

  • Resolution is solid mainstream (133µm at best). Fine for implant visualization; the newest high-res units go finer, but the real-world difference is marginal for case communication.
  • Field of view reaches 14.5cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • It's 17 years old (2009) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
  • Detector: amorphous silicon flat panel.
  • This model is no longer sold new (succeeded by the SCANORA 3Dx) — which means parts, service, and software support are the thing to verify before any new spend.

What it already does that most practices don't use

  • Multiple FOV modes (60x60 mm, 75x100 mm, 100x75 mm, 100x130 mm, 130x145 mm). Most operators leave it on one preset — the larger modes are already paid for.
  • Output/networking: DICOM 3.0 export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the Soredex SCANORA 3D

  • UpgradeMulti-FOV dedicated CBCT (also offered an optional panoramic program on some configs). Several selectable cylinder FOVs from 60x60 mm up to ~130x145 mm; isotropic voxels 133-350 um. Superseded by SCANORA 3Dx (wider FOV, finer voxel).
  • SuccessorThe SCANORA 3Dx is the current successor — useful as a yardstick for what actually changed, not an automatic reason to buy it.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Parts & service (legacy unit): because this model is no longer sold new, parts and service availability — not the sticker — decide whether a repair is worth it. Confirm both before any spend.

Replace: a comparable unit runs roughly ~$20k-$45k used (new discontinued). The honest test before spending that is whether a networking or software path gets you most of the capability for a fraction of it — for an aging machine, it usually does.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

Soredex SCANORA 3D — common questions

Can Alvea use scans from the Soredex SCANORA 3D?
Yes. The Soredex SCANORA 3D exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
Is the Soredex SCANORA 3D discontinued, and what replaced it?
The Soredex SCANORA 3D is no longer sold new; its successor is the SCANORA 3Dx. An aging unit is rarely a reason to replace on its own — parts, service and a software/networking path usually keep it clinically current for far less than a new machine.
How much does a Soredex SCANORA 3D cost?
A comparable Soredex SCANORA 3D runs roughly ~$20k-$45k used (new discontinued). Before replacing, weigh whether a networking or software path gets you most of the capability for a fraction of that.
How much does it cost to repair a Soredex SCANORA 3D?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the Soredex SCANORA 3D?
The Soredex SCANORA 3D reaches 14.5 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a Soredex SCANORA 3D scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my Soredex unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.