MyRay (Cefla)current

MyRay (Cefla) MyRay Hyperion X9
CBCT capability & upgrade report

MyRay Hyperion 2D/3D · released 2013 · 13 yrs in service · current
✓ Works with Alvea. Your MyRay (Cefla) MyRay Hyperion X9 produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution75 µm voxel
Field of view5–11 cm
Capture modes5x5, 8x5, 8x8, 11x5, 11x8
DetectorAmorphous silicon flat panel (CBCT); CCD for 2D panoramic
Scan timeCBCT ~18 s (min); Pan ~7.5-13 s; Ceph ~3.4 s
Pan / CephIntegrated 2D + 3D
Released2013
In service13 years
StatusCurrent
Export pathStandard DICOM
Market positionMid/high-end hybrid pan-ceph-CBCT for general and specialist practices

Where the MyRay (Cefla) MyRay Hyperion X9 stands today

  • Resolution holds up: at its sharpest (75µm voxel) it's still in the fine-detail tier the newest units sell on. You are not behind on image quality.
  • Field of view tops out at 11cm — single-arch range. Good for localized implant work; whole-jaw cases need the larger-FOV path (below).
  • It's 13 years old (2013) — legacy hardware. The question isn't "is it old," it's "does a networking/software path get you current for a fraction of a new unit." Usually yes.
  • Detector: Amorphous silicon flat panel (CBCT); CCD for 2D panoramic.

What it already does that most practices don't use

  • Multiple FOV modes (5x5, 8x5, 8x8, 11x5, 11x8). Most operators leave it on one preset — the larger modes are already paid for.
  • The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the MyRay (Cefla) MyRay Hyperion X9

  • UpgradeFlagship MyRay hybrid pan/(ceph)/CBCT; optional cephalometric module; 16-bit grayscale; 0.5 mm focal spot; max 11 cm diameter FOV collimated to smaller sizes.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

MyRay (Cefla) MyRay Hyperion X9 — common questions

Can Alvea use scans from the MyRay (Cefla) MyRay Hyperion X9?
Yes. The MyRay (Cefla) MyRay Hyperion X9 exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
How much does it cost to repair a MyRay (Cefla) MyRay Hyperion X9?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the MyRay (Cefla) MyRay Hyperion X9?
The MyRay (Cefla) MyRay Hyperion X9 reaches 11 cm, single-arch range suited to localized implant work.
Your cone-beam, chairside

See what a MyRay (Cefla) MyRay Hyperion X9 scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my MyRay (Cefla) unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.