Dabi Atlantecurrent

Dabi Atlante Eagle Edge
CBCT capability & upgrade report

Eagle · released 2022 · 4 yrs in service · current
✓ Works with Alvea. Your Dabi Atlante Eagle Edge produces the DICOM volume Alvea works from — its scans convert to a chairside 3D model with no new hardware. It runs off the cone-beam you already take; nothing to install on the machine.

Specifications

Sharpest resolution75 µm voxel
Field of view5–16 cm
Capture modes5x5, 9x6, 9x9, 14x9, 16x9, 16x15, 16x21
Pan / CephIntegrated 2D + 3D
Released2022
In service4 years
StatusCurrent
Export pathStandard DICOM
Market positionCurrent Dabi Atlante flagship CBCT with wide voxel range

Where the Dabi Atlante Eagle Edge stands today

  • Resolution holds up: at its sharpest (75µm voxel) it's still in the fine-detail tier the newest units sell on. You are not behind on image quality.
  • Field of view reaches 16cm — enough for both arches in one capture. Most practices never switch out of the small default FOV and never know they have this.
  • At 4 years (2022) it's current-generation. There is no hardware reason to replace it — the value left on the table is in how you use it.

What it already does that most practices don't use

  • Multiple FOV modes (5x5, 9x6, 9x9, 14x9, 16x9, 16x15, 16x21). Most operators leave it on one preset — the larger modes are already paid for.
  • The same unit does panoramic/ceph as well as 3D — one capture surface you may be sending out for.
  • Output/networking: standard DICOM export. That export path is what lets a scan leave the machine and become something a patient can actually look at.

Upgrade paths for the Dabi Atlante Eagle Edge

  • UpgradeIsotropic voxel 75-400um; 4 reconstruction filters (Low noise/Standard/HD/UHD); 10th-gen Intel Core i5 workstation. FDA cleared K223816.
  • NetworkThe fastest upgrade is almost never new hardware — it's getting the volume off the machine and into a workflow. That alone changes what the box is worth to you.
  • ReconfigureSwitching your default to the right FOV/scan mode for implant cases is free, and most practices never do it.

Repair vs. replace: what it costs

Repair: the dominant wear item on any dental CBCT is the X-ray tube — a replacement runs roughly $15,000-$40,000, typically every 3–7 years depending on scan volume. A larger-FOV unit like this one sits toward the upper end of that range. Budget a service contract at about $5,000–$15,000/year and software licensing around $2,000/year. A flat-panel detector is the big unknown — it isn't publicly priced, so get a manufacturer quote before assuming the worst.

Replace: replacement pricing varies by configuration and condition. Before any trade-up, the honest test is whether a networking or software path gets you most of the capability for a fraction of a new unit.

Figures are 2025–26 industry ranges for dental CBCT, not a quote for your exact unit or contract. Sources: Medical Imaging Specialists, DentalTI buyer's guide, The Dental Signal.

Dabi Atlante Eagle Edge — common questions

Can Alvea use scans from the Dabi Atlante Eagle Edge?
Yes. The Dabi Atlante Eagle Edge exports a standard DICOM volume, and Alvea converts that volume into a chairside 3D model of the patient's jaw — no new hardware and no new scan. It runs off the cone-beam you already take.
How much does it cost to repair a Dabi Atlante Eagle Edge?
The dominant repair on any dental CBCT is the X-ray tube, which runs roughly $15,000-$40,000 and is typically replaced every 3–7 years by scan volume. Annual service contracts run about $5,000–$15,000, and a flat-panel detector is quoted by the manufacturer rather than listed publicly. These are 2025–26 industry ranges, not a quote for a specific unit.
What is the field of view on the Dabi Atlante Eagle Edge?
The Dabi Atlante Eagle Edge reaches 16 cm, enough to capture both arches in one scan — a mode most practices never switch to.
Your cone-beam, chairside

See what a Dabi Atlante Eagle Edge scan becomes.

Run the free, independent report on your exact unit — then turn one of your own scans into a 3D model the patient can see before they decide. No new hardware, no new scan.

Check my Dabi Atlante unit → Try it on one of my scans — first one's free
Independent by design. Alvea makes nothing you'd buy from a CBCT vendor — so this report has no reason to push you toward a sale. It reads your machine, not your patients. This is an equipment capability report, not clinical guidance.